verilator/test_regress/t/t_lint_blksync_bad.out

18 lines
1.1 KiB
Plaintext
Raw Normal View History

%Warning-BLKSEQ: t/t_lint_blksync_bad.v:24:16: Blocking assignment '=' in sequential logic process
: ... Suggest using delayed assignment '<='
24 | sync_blk = 1'b1;
| ^
2021-04-24 14:33:49 +00:00
... For warning description see https://verilator.org/warn/BLKSEQ?v=latest
... Use "/* verilator lint_off BLKSEQ */" and lint_on around source to disable this message.
%Warning-BLKSEQ: t/t_lint_blksync_bad.v:25:17: Blocking assignment '=' in sequential logic process
: ... Suggest using delayed assignment '<='
25 | sync_blk2 = 1'b1;
| ^
%Warning-COMBDLY: t/t_lint_blksync_bad.v:31:18: Non-blocking assignment '<=' in combinational logic process
: ... This will be executed as a blocking assignment '='!
31 | combo_nblk <= 1'b1;
| ^~
2021-04-18 15:52:29 +00:00
*** See https://verilator.org/warn/COMBDLY before disabling this,
else you may end up with different sim results.
%Error: Exiting due to