verilator/test_regress/t/t_lint_always_comb_bad.out
2024-03-02 10:15:19 -05:00

20 lines
1.3 KiB
Plaintext

%Error-PROCASSWIRE: t/t_lint_always_comb_bad.v:29:9: Procedural assignment to wire, perhaps intended var (IEEE 1800-2023 6.5): 'temp1'
: ... note: In instance 't'
29 | temp1 = 'h0;
| ^~~~~
... For error description see https://verilator.org/warn/PROCASSWIRE?v=latest
%Error-PROCASSWIRE: t/t_lint_always_comb_bad.v:31:9: Procedural assignment to wire, perhaps intended var (IEEE 1800-2023 6.5): 'temp1'
: ... note: In instance 't'
31 | temp1 = (temp1_d1r - 'h1);
| ^~~~~
%Warning-ALWCOMBORDER: t/t_lint_always_comb_bad.v:32:7: Always_comb variable driven after use: 'mid'
: ... note: In instance 't'
32 | mid = (temp1_d1r == 'h0);
| ^~~
... Use "/* verilator lint_off ALWCOMBORDER */" and lint_on around source to disable this message.
%Error-PROCASSWIRE: t/t_lint_always_comb_bad.v:46:7: Procedural assignment to wire, perhaps intended var (IEEE 1800-2023 6.5): 'temp1_d1r'
: ... note: In instance 't'
46 | temp1_d1r <= temp1;
| ^~~~~~~~~
%Error: Exiting due to